Power up to 20 MVA -33 kV. Distribution up to 5 MVA - 33 kV, Furnace up to 10 MVA - 33 kV, Rectifier up to 10 KA DC - 33 kV, Reactor up to 2 MVA - 33 kV , Earthing up to 2 MVA - 33 kV, Converter Duty up to 10 MVA - 33 kV, Dry (VPI / CRT ) up to 5 MVA - 33 kV. - with OLTC also.
Power
Station & Multi-winding to suit specific needs & L.T. Transformers for generating Stations.
Upto 20 MVA ,3 Phase , Upto 33Kv , ONAN/ONAF/OFAF /OFWF Cooling For Power transformers, the short circuit withstand capability is of prime importance. This is achieved by us through the adoption of a unique clamping arrangement of the windings and accurately determined pre-stress. It is characterized by inner and outer low voltage winding sections and a high voltage winding section disposed there between. The low voltage windings are comprised of a plurality of pancake coils, and the high voltage winding are comprised of a plurality of conductor strands spirally wound for a plurality of coil layers. The low and high voltage winding sections are laterally spaced with the low voltage windings disposed in side-by-side positions and adjacent to the high voltage windings.
Distribution
Industrial, Substation & Distribution Transformer up to 10 MVA, up to 33kV, ONAN
A poly phase transformer design is presented in which transformer output pores are accurately constructed in both voltage magnitude and relative phase angle. The design incorporates both main and auxiliary transformers that are used in unison to produce the accurately constructed phases. The main transformer permits rough phase adjustment to be made with the auxiliary transformer permitting phase fine tuning. Such a design is particularly suitable in transformer approaches that require output phases that are of a number not evenly divisible by three.e cleaned and each device undergoes appropriate testing.
Furnace
Arc,Submerged Arc, Ladle , Induction , upto 10 MVA upto 33 kV. ONAN/OFWF Cooling.
A high current furnace transformer is provided having the low-voltage windings arranged in a closed delta configuration within the transformer enclosure. Bus bar terminals are mounted exterior to the enclosure for providing electrical connection with the low-voltage windings
Rectifier
Six or Twelve Pulse with IPT (Double bridge construction), Up to 10 KA DC, Up to 33kV, ONAN/OFWF cooling.
A rectifier transformer circuit permitting six-phase double-wye operation with 120.degree. conduction, (without the use of an inter phase transformer), and providing any predetermined degree of phase shift. The transformer comprises a zigzag wye primary winding and a six-phase star secondary winding. By choosing the proper ratio for the turns of the zig and zag portions of the primary winding, any degree of phase shift can be obtained. The rectifier transformer is ideally suited for multiple-phase installations wherein several rectifier transformers are used, each providing a different amount of phase shift, without the use of separate phase-shift transformers.